The Accuro Gas Detector Pump is a manually operated bellows pump that draws a calibrated 100 milliliter sample through the short-term Dräger-Tubes. The Accuro Pump features one-hand operation, very low maintenance, end-of-stroke indicator and comes with a built-in automatic stroke counter. Draeger Safety
Nylon Transport Carrying Case for G1000, Draeger Hand Operated Bellows Pump. Draeger Safety
For Draeger apparatus. For short-term measurements more than 160 Dräeger Tubes are available to measure spot concentrations of specific gases. A wide range of different gases and vapors can be detected and measured; Determining and measuring concentration peaks, Measuring personal exposure in the inhalation area, Detecting leaks in pipelines, gas installations etc., and Air analysis in sewers, shafts and confined spaces. Other gas detecting tubes are available. Please inquire for[…] Draeger Safety
The Model GV-100-S-TR Gas Sampling Pump can precisely collect a sample volume for a detector tube. The full-stroke (100 ml) and the half stroke (50 ml) positions are marked exactly by the red line on the pump shaft, and the handle is precisely locked at those positions. If you pump fully "n" times by allowing for sampling time intervals, a volume of 100 ml x "n" can be sampled. Each detector tube is calibrated based upon a prescribed (standard) volume of sample. Also, the pump piston has[…] NEXTTEQ
Sample tubes for the Gastec Model 800 pump. 10 sample tubes per pack. NEXTTEQ
Tutweiler Gas Apparatus. For determining hydrogen sulfide in natural gas and in gas mixtures. Reads directly in grains/100 cu. ft. of sample. The method is simple and the results are within the limits necessary for control analysis. Two solutions are used -- standard iodine and starch. Complete with parts as shown, including 100ml. burrette, in wooden carrying case w/o solutions. Burrell
Burrell Senior Model 410. For use where the components of the gas mixture consists of other than oxygen, carbon dioxide and carbon monoxide. Supplied with three "Auto-Bubbler" pipettes; one "Contact" pipette; 10ml measuring burette, without reservoir; Perma-Therm catalyst heater. Supplied without reagents. In carrying case. 115v. Burrell
For use with Burrell Gas Analysis Apparatus. Made of borosilicate glass. Stopcock is bored to permit flow between any two adjacent openings. Burrell
Bottom portion graduated 0-30ml, in 0.1ml and made of Schellbach tubing. Bulb contains 70ml. For use in analyzer G1240. Burrell
Made of Schellbach tubing. Bottom portion graduated to 30ml, in 0.2ml subdivisions; expanded bulb portion graduated to 70ml, in 0.5ml subdivisions. For use in analyzer G1260. Burrell
Water reservoir which surrounds burettes G1340, G1360 and G1380. G1400-1 is used on G1240 and G1280. G1400-2 is used only on G1260. Burrell
Be-Te "Auto-Bubbler" type. Borosilicate glass. For use with all Burrell Build up and Cabinet model gas analysis apparatus. The tapered valve chamber permits positive control of the absorbing reagent and reduces the possiblity of solution containmention in the maniford capilary. Used with G1240 and G1280. Burrell
Contact type. Borosilicate glass. Front chamber is filled with glass tubes to increase absorptive surface. Has copper turning in front chamber. Used with G1260 and G1280. Burrell
Gas Expansion Bag with first quality rubber. Comes with tubing. Has suffucuent capacity and design for gas analysis work. These bags are attached to the rear chamber of the absorption pipettes to prptect the solution form contact with air. Burrell
A solution for absorption of oxygen. Absorbs four times its volume of oxygen. Slightly acid which prevents stopcocks sticking. Absorbs oxygen rapidly. For use with pipette G1420. 8 oz. bottle. Burrell
For absorption of carbon dioxide, also hydrogen sulfide, sulfur oxides and other acidic gases. For use with contact pipette G1460. 16 oz. bottle. Burrell
For absorption of carbon monoxide, also ethylene, propylene and acetylene. Recommended for use with pipette G1420. 8 oz. bottle. Burrell
This fluid is formulated for the detection of leaks in gas lines, gas connections, and other applications when an airtight seal is necessary. Apply a few drops of this fluid on a connection, and any leak will be detected. Bottle with dispenser top contains 8 oz. Nupro